PERFORMANCE DATA:
(Based
on inlet air temperature 21°C
the chart gives
approximate temperature drops and rises from the
inlet air temperature)
|
Inlet
Pressure
kPa
|
|
COLD
FRACTION
(Cold
Fraction is the percentage of the total
flow which comes out as cold air)
60%
Cold
Fraction setting is typical
|
|
20%
|
30%
|
40%
|
50%
|
60%
|
70%
|
80%
|
|
140
|
Temperature
drop
|
17,3°C
|
16,3°C
|
13,4°C
|
10,7°C
|
7,0°C
|
2,8°C
|
1,8°C
|
|
Temperature
increase
|
9,4°C
|
4,2°C
|
3,2°C
|
10,7°C
|
18,4°C
|
28,1°C
|
42,3°C
|
|
280
|
Temperature
drop
|
31,8°C
|
29,9°C
|
27,3°C
|
22,9°C
|
17,3°C
|
11,4°C
|
4,0°C
|
|
Temperature
increase
|
4,8°C
|
1,8°C
|
11,2°C
|
22,9°C
|
33,8°C
|
47,2°C
|
64,6°C
|
|
410
|
Temperature
drop
|
40,2°C
|
38,8°C
|
34,3°C
|
29,0°C
|
23,1°C
|
16,1°C
|
7,5°C
|
|
Temperature
increase
|
3,6°C
|
4,4°C
|
15,1°C
|
29,0°C
|
40,1°C
|
56,2°C
|
76,2°C
|
|
550
|
Temperature
drop
|
47,3°C
|
44,6°C
|
39,1°C
|
33,5°C
|
27,4°C
|
19,0°C
|
10,1°C
|
|
Temperature
increase
|
3,3°C
|
6,7°C
|
17,8°C
|
33,5°C
|
45,6°C
|
62,4°C
|
82,9°C
|
|
700
|
Temperature
drop
|
53,5°C
|
48,7°C
|
44,0°C
|
38,0°C
|
30,3°C
|
22,2°C
|
12,0°C
|
|
Temperature
increase
|
2,3°C
|
7,8°C
|
19,6°C
|
38,0°C
|
48,9°C
|
66,2°C
|
89,0°C
|
|
|